All you need to know about CE Marking
Need answers fast? Book a free 30-min consultation
What Is a Bill of Materials (BOM)? How to Compile It, With an Ideal BOM Example
A Bill of Materials, or BOM, is the structured, hierarchical list of every component, subassembly, part, material and, at its most detailed level, every substance that makes up a physical product. At the top sits the finished product. Below it sit assemblies and subassemblies. At the bottom sit individual materials and the chemical substances they contain.
The BOM sits at the core of RoHS documentation, and Spain (where we are based) makes that clearer than most. Spanish customs apply documentary RoHS controls more strictly than almost any other EU Member State. Companies contact us after their shipment is already stuck at the border. Some reroute through Rotterdam, where checks are lighter, then move goods into Spain by road.
To avoid situations like this, it is worth reading this guide carefully. Every component and every material in a product carries its own compliance requirement, and demonstrating that is often harder than it looks.
What Are the Different Types of BOM?
Engineering BOM (EBOM): reflects the design of the product, generated from a CAD or PLM system and organized by functional logic.
Manufacturing BOM (MBOM): reflects how the product is actually assembled, adding what the design view leaves out: adhesives, solder, coatings, labels, packaging and the assembly sequence.
Homogeneous material BOM: the most granular view, where each part is decomposed until you reach materials that cannot be separated from one another by mechanical means. This is the level RoHS and REACH enforce their limits at, and the level most manufacturers do not have documented.
No regulation explicitly requires a specific BOM format.
In practice, most manufacturers work in Excel or in a PLM system that can export to Excel.
For each homogeneous material, a compliance-grade BOM needs to carry:
- Part number
- Manufacturer and manufacturer part number
- Material description
- Weight
- Substances present with their concentrations
- Conformity status
- Any exemption relied upon, with its Annex III or IV reference and expiry date
Standardized exchange formats exist for sharing this data with suppliers and customers: IEC 62474, IPC-1752A and chemSHERPA are the most widely used in the electronics supply chain. None of these is legally required, but they are faster to process and harder to misread than a bespoke spreadsheet.
A BOM lists physical parts. Its software counterpart, the Software Bill of Materials (SBOM), does the same for code, identifying every component and dependency inside a digital product. Both are increasingly relevant for connected products subject to EU regulation.
BOM and CE Marking: Regulations That Require It
The CE marking technical file sits at the center of every CE marking conformity exercise. The component list is part of that file. It identifies what the product contains, links each part to the applied harmonised standards and test results, and supports the risk analysis. The file must be retained for ten years after the last unit is placed on the market and produced for market surveillance on request.
The Low Voltage Directive, the EMC Directive and the Radio Equipment Directive all require a manufacturer who knows exactly what goes into the product and can trace each component to its evidence.
The Machinery Regulation (EU) 2023/1230, applicable from 20 January 2027, makes the dependency clear. A machine is an assembly of bought-in parts: motors, drives, sensors, guards, control components, fasteners, wiring. The technical file has to show that each of these meets its requirements. The risk assessment depends on knowing which components are present and where they sit in the machine. An incomplete BOM produces a gap in the risk assessment, and a gap there means the technical file cannot support the Declaration of Conformity.
What RoHS Actually Says About the BOM
Directive 2011/65/EU restricts hazardous substances in electrical and electronic equipment. Delegated Directive (EU) 2015/863 extended the original list from six substances to ten by adding four phthalates. The restricted substances are lead, mercury, cadmium, hexavalent chromium, PBB, PBDE, DEHP, BBP, DBP and DIBP, all capped at 0.1% by weight except cadmium, which is capped at 0.01%.
Those limits apply per homogeneous material. Article 3(20) defines homogeneous material as one material of uniform composition throughout, or a combination of materials that cannot be separated into different materials by mechanical actions such as unscrewing, cutting, crushing, grinding or abrading. A solder joint, a coating, a wire insulation layer, a plating, a resin: each one is a separate homogeneous material and each has to meet the limit on its own. A high-lead solder joint cannot be diluted across the weight of the whole product.
The harmonised standard for RoHS technical documentation is EN IEC 63000:2018. It replaced EN 50581:2012, whose reference was withdrawn from the Official Journal on 18 November 2021 by Commission Implementing Decision (EU) 2020/659. Declarations of Conformity issued today should reference EN IEC 63000:2018. Any DoC still citing EN 50581 is out of date.
EN IEC 63000:2018 takes a risk-based approach. The manufacturer does not have to test every homogeneous material.
The file combines engineering judgment, supplier material declarations and analytical testing in proportion to the risk each part presents. A commodity component from a reliable supplier may need only a declaration. An unfamiliar or high-risk part warrants testing.
Exemptions are easy to overlook. Annexes III and IV of the Directive list time-limited exempted applications. Renewal requests must be filed at least eighteen months before expiry. A product built entirely from components with individually compliant declarations can still be non-compliant if an exemption it relies on has lapsed by the date the product is placed on the market. That’s why an exemption register, kept per SKU, part and material, needs updating for as long as the product is on the market.
There are no laboratories accredited to certify RoHS. The regime runs on self-declaration, and no notified body issues a RoHS certificate. The relevant credential when assessing a laboratory is ISO/IEC 17025 accreditation for the specific test methods used. That covers the competence of the testing, not RoHS compliance as such, and it is the only laboratory credential that carries weight in a RoHS file. The full restriction list and its annexes are in Directive 2011/65/EU.
What Other EU Regulations Require a BOM?
REACH Article 33 requires suppliers to communicate information when an article contains a Substance of Very High Concern above 0.1% by weight. Following the Court of Justice ruling in case C-106/14, that threshold applies to each individual article, not to the finished product as a whole. A small SVHC-bearing component cannot be diluted across the assembly weight. The ECHA Candidate List updates twice a year, so the BOM needs to be screened against the current list on a recurring basis.
The Battery Regulation (EU) 2023/1542 ties material composition to recycled-content minimums, carbon-footprint declarations and supply-chain due diligence. It introduces a battery passport, mandatory from 18 February 2027 for EV, LMT and larger industrial batteries.
The ESPR (EU) 2024/1781 creates the framework for the Digital Product Passport, which will require composition data, the location of substances of concern within the product, and recyclability information, rolled out group by group through delegated acts.
The Packaging and Packaging Waste Regulation (EU) 2025/40, applicable from 12 August 2026, requires knowing the material composition of packaging to assess recyclability grades and recycled content.
The Conflict Minerals Regulation (EU) 2017/821 requires EU importers of tin, tantalum, tungsten and gold to exercise due diligence on their supply chain. Manufacturers of finished products are not directly covered, but their customers often send them due diligence requests, and answering those requires knowing where 3TG appear in the BOM.
RoHS Testing Methods: Non-Destructive and Destructive
Non-destructive methods screen without damaging the sample. X-ray fluorescence (XRF), covered by IEC 62321-3-1, screens for lead, mercury, cadmium, total chromium and total bromine. It is fast and can be applied to finished parts and assemblies. XRF detects elements, not compounds, so it cannot distinguish hexavalent chromium from total chromium or identify which brominated compound is present. FTIR plays a similar screening role for certain polymers and coatings.
Destructive methods confirm what screening flags, and consume the sample in the process. IEC 62321-5 quantifies cadmium, lead and chromium by AAS, ICP-OES or ICP-MS. IEC 62321-4 covers mercury. IEC 62321-6 identifies PBB and PBDE by GC-MS. IEC 62321-7 measures hexavalent chromium by a colorimetric method. IEC 62321-8 handles phthalates by GC-MS.
The practical workflow is tiered: screen with XRF first, then send for destructive chemical analysis only the parts that land in a gray zone or exceed a threshold. Testing every homogeneous material in a complex product is neither necessary nor proportionate.
Bill of Materials Example and Template: The Ideal Compliance BOM
Everything above comes together in one document. Here’s what we consider the ideal compliance BOM, the most complete version we’d hope to find in a technical file. It belongs to the same fictional IoT device we use in our CE marking user manual example, and it tracks RoHS and REACH in the same table.
Example: the ideal compliance Bill of Materials (fictional company)
BRIGHTVALECONTROLS
COMPLIANCE BILL OF MATERIALS
IoT Device BVS-200 V2 · RoHS 2011/65/EU and REACH (EC) 1907/2006
Scroll sideways to see all columns →
| Level Essential | Part no. Essential | Description Essential | Qty Essential | Material Essential | Supplier Essential | RoHS status Essential | REACH: SVHC > 0.1% w/w Recommended | REACH risk Advanced | Evidence Essential | Action Advanced |
|---|---|---|---|---|---|---|---|---|---|---|
| 0 | BVS-200-V2 | IoT Device BVS-200 V2, final assembly | 1 | See lines below | Brightvale Controls | |||||
| 1 | EN-200-01 | Enclosure, top | 1 | PC/ABS | Supplier A | Compliant | None > 0.1% | Low | Supplier material declaration, current Candidate List | |
| 1 | EN-200-02 | Enclosure, bottom | 1 | PC/ABS | Supplier A | Compliant | None > 0.1% | Low | Supplier material declaration, current Candidate List | |
| 2 | IN-M3-BR | Threaded insert M3 (4 per enclosure) | 4 | Leaded brass CuZn39Pb3 | Supplier B | Exemption 6(c), lead in copper alloy up to 4% | Lead, CAS 7439-92-1, approx. 3% | High | Supplier declaration and alloy certificate | Article 33 information to customers. SCIP notification |
| 1 | PCBA-200 | Main board assembly | 1 | See lines below | Supplier C (EMS) | |||||
| 2 | PCB-200 | Printed circuit board | 1 | FR-4 laminate, copper, ENIG finish | Supplier C | Compliant | None > 0.1% | Low | IPC-1752A declaration, current Candidate List | |
| 2 | SLD-SAC | Solder joints | n/a | Lead-free solder SAC305 | Supplier C | Compliant | None > 0.1% | Low | IPC-1752A declaration, current Candidate List | |
| 2 | WM-24 | Wi-Fi module (pre-certified) | 1 | Assembled component | Supplier D | Compliant | Declaration older than the current Candidate List | Medium | Supplier declaration, Sep 2025 | Request updated SVHC declaration |
| 1 | GS-200 | Enclosure gasket | 1 | Silicone rubber | Supplier E | Compliant | D4, D5, D6 siloxanes possible as residues | Medium | Supplier confirmation pending | Ask for test report or supplier confirmation |
| 1 | CB-200 | Power cable, 1.5 m | 1 | Copper conductor, flexible PVC insulation | Supplier F | Phthalates to be confirmed | Phthalates (DEHP, DBP, BBP, DIBP) possible in flexible PVC | High | No declaration on file | Hold release until declaration and test report are received |
| 1 | PSU-12V | External power supply, 12 V | 1 | Purchased CE marked article | Supplier G | Compliant (supplier DoC) | Not declared | Medium | Supplier EU DoC only | Request SVHC declaration for the complete article |
| 1 | SC-M3 | Screw M3 x 8 (4 per unit) | 4 | Carbon steel, zinc plated | Supplier H | Compliant | None > 0.1% | Low | Supplier declaration, current Candidate List | |
| 1 | LB-200 | Rating label | 1 | Polyester film, acrylic adhesive | Supplier I | Compliant | None > 0.1% | Low | Supplier declaration, current Candidate List | |
| 1 | PK-SPEC-0417 | Sales packaging | 1 | Paperboard, molded pulp, LDPE | Supplier J | n/a | n/a | Low | Covered by the PPWR Declaration of Conformity | Managed under PPWR, not RoHS |
Column level
Essential The minimum to show which materials are in the product and prove RoHS compliance.
Recommended Needed as soon as REACH applies and you have to know where SVHCs are.
Advanced Turns the BOM into a management tool: risk-based priorities and next actions.
REACH risk level
High The material is known to carry Candidate List substances above 0.1% (for example leaded brass or flexible PVC), or a SVHC is confirmed, or there is no supplier data.
Medium The material can contain SVHCs, or the supplier declaration is older than the current Candidate List.
Low The material is not expected to contain SVHCs and the declaration covers the current Candidate List.
BOM rev. 07 · Reviewed by Laura M. Bennett, CEO · Columbus, Ohio, 20 October 2026
Fictional company, parts and suppliers, shown for illustration only. In a real compliance BOM, every homogeneous material gets its own line and its own evidence.
Use it as a reference and adapt it. Very few companies keep a BOM this complete, and many don’t need to. The right level depends on how many parts and suppliers you manage, which regulations apply to your product, and the tools you already work with, whether that’s a spreadsheet or a PLM or ERP system.
That’s why each column carries a level.
The essential columns are the minimum. They identify every part and material, its supplier, its RoHS status and the evidence behind it. Without them, the BOM can’t support the RoHS documentation in the technical file.
The recommended column adds REACH. It records whether a part contains a Candidate List substance above 0.1% by weight, which is the information Article 33 requires you to pass on to your customers.
The advanced columns turn the BOM into a management tool. The risk level shows where to look first: leaded brass, flexible PVC and supplier declarations older than the current Candidate List go to the top. The action column records what is still open, so nothing gets lost between one review and the next.
Packaging appears in the BOM too, but it’s managed under the PPWR. In the example, the sales packaging is covered by its own PPWR Declaration of Conformity.
A manufacturer with a few dozen parts can start with the essential columns and add the others as time and resources allow. The one thing every version needs is a clear trail from each homogeneous material to its evidence.
CE Marking Basics
Explore the full series:
- How to Get CE Marking
- Declaration of Conformity
- Technical File
- Bill of Materials
- User Manual
- Risk Assessment and Machinery Risk Assessment
- Testing and Pre-Testing
- Notified Bodies
- Authorised Representative
- Placing on the Market
- Substantial Modification
- Selling without CE Marking
- Best Consultants 2026
What you can do: start by assessing your supplier DoCs
If you hold a Declaration of Conformity for every component, and every one of those declarations is fully reliable, your RoHS compliance is demonstrated on paper without any testing. That is the logic EN IEC 63000:2018 formalises, and for a manufacturer with a stable, well-documented supply chain it is an achievable position.
The route is fast, inexpensive and scales across a large BOM in a way laboratory testing cannot. Its limit is the supplier behind each declaration.
Declarations go stale, get written in generic terms with no reference to a specific standard or test basis, or describe a component revision that no longer matches what is being shipped. A supplier can change a solder alloy, a coating or a sub-supplier without notifying you, and the declaration on file silently stops describing the actual part. A declaration that does not address exemption status can leave you with paperwork that looks clean while the product is not.
The practical approach is to collect every Declaration of Conformity you hold, grade each one for reliability, and reserve analytical testing for the gaps: weak or generic declarations, high-risk materials, components that have changed. A strong RoHS file is mostly paper, with testing applied where the paper does not hold.
If you are not sure whether your supplier declarations would survive a Spanish (or any other) customs inspection, that assessment is the starting point. Get in touch and we can take a look.
Read this far? The next step is a free 30-min consultation
Category: CE Marking