All you need to know about CE Marking

Need answers fast? Book a free 30-min consultation

CE Marking Testing: What You Need To Do for Your Self-Declaration

In a CE marking self-declaration project, testing accounts for roughly 25% of the work. The other 75% sits in the documentation, and that documentation is where market surveillance authorities look first when something goes wrong.

This proportion catches most manufacturers off guard. The instinct is to treat the lab report as the deliverable and the paperwork as supporting material. Under self-declaration, that ordering reverses. The Declaration of Conformity you sign as a manufacturer commits you personally to every claim in the technical file, and any inspection works backwards from your signature through the evidence behind it.

This post walks through what “testing” actually means under each directive, where to run those tests, when to schedule them, and how to handle the document the lab sends back.

Is Testing the Most Important Part of the CE Marking Process?

No. Testing matters, but the bulk of a CE marking file gets built somewhere else. Under self-declaration, no notified body shares the responsibility with the manufacturer. The manufacturer chooses the testing strategy, runs or commissions the tests, and signs the Declaration of Conformity. Everything required to CE mark a product, and to keep it legally on the market, stays on the manufacturer’s side.

The work that does the heavy lifting happens before any test bench gets booked. The compliance assessment maps which directives and harmonized standards apply to the product. The gap analysis measures the distance between the current design and those requirements. The risk assessment identifies what can go wrong and how the design addresses it. The technical file consolidates everything. Testing verifies one specific layer of that work, the technical layer, against requirements defined earlier in the process.

Skip that earlier work and you end up testing in the dark. The lab will pick something reasonable and run it. The resulting report may or may not match the actual regulatory requirements of the product, and fixing the mismatch later costs more than the original test.

What Does “Testing” Actually Mean?

Under the CE marking umbrella, “testing” covers very different activities depending on the directive. Some products go to a laboratory for electrical or chemical work. Others get verified on the production floor. Others clear the requirement through documentary evidence from suppliers. A few mix all three approaches. The sections below illustrate the most common tests through plain examples, without diving into specific standards.

The Classic Tests: LVD and EMC

These are what most people picture when they hear “CE marking testing.” Work under the Low Voltage Directive checks that the product is electrically safe: no shocks, no overheating, no insulation failures under stress. EMC testing checks two things at once. The product should not emit electrical noise loud enough to disturb other devices nearby, and it should keep working when other devices are emitting noise around it.

These tests usually happen in a properly equipped lab, often inside a shielded chamber for EMC and on dedicated benches for high-voltage safety checks.

EMC has one important caveat. For some products, running a chamber test is physically impossible. Large industrial equipment, fixed installations, and machines that cannot operate outside their intended environment fall into this category. When that happens, the route is to build a technical justification: a reasoned argument that demonstrates EMC compliance through analysis, comparison with similar tested products, and the design measures applied. The justification goes into the technical file and replaces the chamber report.

“Tests” in the Machinery World

The quotation marks are deliberate. Under the Machinery Regulation, most of what counts as testing looks nothing like a chamber session. The verification happens on the machine itself, often as part of the design and prototyping phase.

Typical activities include validating that emergency stops cut power within the required time, measuring noise and vibration levels at operator positions, checking that guards prevent access to dangerous areas, and confirming that safety functions behave correctly when a fault is introduced. The records of these verifications sit alongside the risk assessment in the technical file.

Some pieces of a machinery file still go to an external lab, particularly the electrical safety and EMC parts of any control cabinet. The mechanical and functional safety side stays on the shop floor.

RoHS, the Test You Can Avoid

RoHS is the directive where physical testing is optional in practice, and most manufacturers should avoid it. Conformity has two routes.

The first is documentary. You collect RoHS declarations of conformity from each component supplier, evaluate the reliability of those declarations based on the supplier’s reputation and quality system, and consolidate everything into a single technical report. The cost is mostly time.

The second is physical testing. You send each homogeneous material of the product to a lab for chemical analysis. For a machine with hundreds of components, this gets expensive fast, often more expensive than the electrical safety and EMC tests combined.

With reliable suppliers, the documentary route is the better choice. The same logic applies to REACH for many product categories, with an added complication: a REACH test campaign covers a much wider list of substances than RoHS, so the cost gap between documentary and physical routes is larger.

Toy Safety is the exception on the field or chemical safety. The directive does not accept documentary evidence for chemical parameters, so toys go to the lab.

Tests in the RED Universe

The Radio Equipment Directive covers the widest spread of test types of any single directive. At one end sit the classics: LVD and EMC are folded into RED for radio products and run exactly as they would for a non-radio device. At the other end sit tests that have nothing to do with electrical chambers at all.

The clearest example is the cybersecurity stream. Radio products that connect to the internet, manage personal data, or handle payments need to be verified against EN 18031, which deals with how the product handles authentication, software updates, data protection, and resistance to attacks. The work here looks closer to a software audit than to a traditional bench test.

The Cyber Resilience Act extends a similar set of cybersecurity expectations to a much broader class of connected products, including many that fall outside RED. Manufacturers already running EN 18031 work will recognize most of the requirements.

Where to Run the Tests: Three Tiers of Credibility

The question of where to test breaks into three tiers, each with a different weight in the eyes of a market surveillance authority.

Tier 1 covers internal testing. The manufacturer uses its own staff and equipment to run the verifications. Module A allows this for self-declared products. The catch shows up during an inspection. You need to demonstrate that the personnel running the tests have the technical competence, that the equipment is calibrated, and that procedures are written down and followed. Without those three pieces in place, an internal test report carries little weight when challenged.

Tier 2 uses a non-accredited external laboratory. The product goes to an outside lab that operates professionally but does not hold ISO/IEC 17025 accreditation. The main advantage is speed. Non-accredited labs typically book sooner and turn results around faster than accredited ones, which makes them attractive when the project schedule is tight. The trade-off is that some of these labs build the test plan around the availability of their own equipment rather than around the tests the product actually needs, which creates coverage gaps that often surface later when an authority or a customer reviews the report.
Structurally, this option is weaker than the next tier in front of market surveillance authorities, since a non-accredited report does not carry the formal presumption of technical competence that an accredited one does.

Tier 3 uses an ISO/IEC 17025 accredited laboratory. The accreditation gives the test report a presumption of technical correctness that the other two tiers cannot match. The law does not require it for self-declaration, but in any dispute with an authority the difference is significant. A 17025 report is, in practice, very hard to challenge on technical grounds.

The Construction Products Regulation regime illustrates how this hierarchy plays out commercially. CPR allows manufacturer-run testing for certain Declarations of Performance under specific Assessment and Verification of Constancy of Performance systems. A DoP backed by internal testing is legally valid where the regulation permits it, yet it does not enjoy the same acceptance in the market as one backed by a 17025 lab. Buyers, specifiers, and authorities all read the AVCP route on the DoP, and they weight their decisions accordingly.

The choice between tiers comes down to risk tolerance more than to price. The cheaper the testing, the more exposure the manufacturer carries when challenged.

When to Start Testing?

Testing and documentation run in parallel. The common assumption that the technical file gets finished first and the product goes to the lab afterwards costs projects weeks of avoidable delay.

In a well-run project, both streams move at the same time, and the testing schedule sits inside the project plan from day one.

For an external laboratory, the one hard prerequisite is a complete instruction manual. The lab needs it to configure and operate the product correctly during the tests, particularly for safety-relevant settings, intended use limits, and the operating modes that have to be verified. Without a finished manual, the lab either improvises, in which case you risk getting tested against the wrong configuration, or refuses the job.

For internal testing the threshold is lower. As soon as the gap analysis is complete and the applicable standards have been identified, the work can start. Doing this under consultancy supervision is the safest approach, because it ensures the internal tests target the right requirements and produce records that hold up in the technical file later.

The practical consequence is that a serious CE marking project does not wait. Documentation work, design verification, and lab booking advance on overlapping timelines, and the project finishes faster.

There Is No “CE Certificate” in Self-Declaration

Cross-border trade generates constant confusion on this point. Importers, distributors, retail platforms, and procurement departments routinely ask for the “CE certificate” of a product. When the product is self-declared, no such document exists.

The laboratory issues a test report at the end of a test campaign. The report describes the tests performed, the standards applied, the measurements taken, and whether the product passed each one. The lab signs it, and it carries technical evidence rather than regulatory authorization.

The Declaration of Conformity carries the CE marking legally. The manufacturer writes it, signs it, and stands behind it. The DoC lists the directives the product complies with, the standards applied, and the test reports that support the claim. The technical file holds the underlying evidence.

Certificates in the strict sense exist only when a notified body is involved. An EU-type examination certificate, for example, comes out of a Module B assessment performed by an accredited notified body. In self-declaration, no such certificate ever gets issued, and any document calling itself a “CE certificate” for a self-declared product is either a marketing nickname for a test report or a fabrication. Both create real legal risk when presented to customs, distributors, or authorities as official.

For help building a CE marking file that holds up under scrutiny, including the testing strategy that fits the product and the directives in play, request a quote.

Category: CE Marking
Tags: ce certificate self-declaration, ce marking testing, ce marking testing requirements, ce marking without notified body, ce testing laboratory, internal testing ce marking, iso 17025 ce testing, self-declaration ce marking, test report ce marking

You Fill This Form.